日韩AV高清无码,大明荫蒂女人毛茸茸,亚洲日韩欧美一区二区三区,精品无码AV一区二区三区不卡

免費咨詢熱線:
產品中心
首頁 > 產品中心 > 代理 > 代理品牌 > Flow Tech Inc.血管造影劑代理

Flow Tech Inc.血管造影劑代理

簡要描述:北京百奧創新代理 Flow Tech Inc.在中國的業務。 Flow Tech Inc.代理, Flow Tech Inc.血管造影劑代理, Flow Tech Inc.代理, Flow Tech Inc.華東代理, Flow Tech Inc.華北代理, Flow Tech Inc.華中代理 Flow Tech Inc.華南代理

  • 產品型號:型號齊全
  • 廠商性質:代理商
  • 更新時間:2024-12-17
  • 訪  問  量:1981
詳情介紹

北京百奧創新代理 Flow Tech Inc.在中國的業務。  Flow Tech Inc.血管造影劑代理 Flow Tech Inc.代理, Flow Tech Inc.華東代理, Flow Tech Inc.華北代理, Flow Tech Inc.華中代理, Flow Tech Inc.華南代理


Flow Tech Inc.代理  Flow Tech Inc.血管造影劑代理

Prices and Available Colors

Kit

Weight

Color

Price

B

1 lb.

One color

$150

C

2 lbs.

One or two colors

$275

D

1 gal. (8 lbs.)

One to four colors

$950

Kit weight is based upon the combined weight of MV-Compound and MV-Diluent only, ie. a 1lb. kit contains 8 oz. of MV compound and 8 oz. of diluent.

Sufficient MV-Curing Agent is supplied at no charge to cure the contents of the kit.

A one pound kit has a volume of approximay 400 ml.

MICROFIL廬 CP-101 For Cast Corrosion Preparations

Kit

Weight

Color

Price

CP-101

1 lb.

Milky

$140

Kit weight is based upon the weight of MICROFIL廬 CP-101 (16 oz.). Sufficient curing agents are supplied at no charge to cure the contents of the kit.

Curing System

Stannous octoate in combination with ethyl silicate.

Mixing Directions

Cure is accomplished by mixing CP-101 with 5% ethyl silicate and 5% stannous octoate (by weight). Upon addition of curing agents, working time is approximay 45 minutes.

Clearing Procedure

Either alcohol-methyl salicylate or glycerin may be employed.聽See more details.

Corrosion Preparations

Potassium hydroxide may be used in studies where the vessels have a diameter of greater than 100 microns.

Corrosion Clearing Procedure

Cast corrosion can be obtained as follows: After the casting material has been compley hardened, place the perfused organ in 20% potassium hydroxide or sodium hydroxide solution for several days. The cast should then be rinsed several times in water until all the tissue is removed. The casting time depends both on the concentration of the corrosive solution and on the tissue itself. Lung and heart tissue require 5-6 days in potassium hydroxide whereas bone and brain tissue may require 35% potassium hydroxide for up to 10 days.

Advantages

MICROFIL CP-101 will maintain dimensional integrity on storage. There is no diluent in the system.



留言框

  • 產品:

  • 您的單位:

  • 您的姓名:

  • 聯系電話:

  • 常用郵箱:

  • 省份:

  • 詳細地址:

  • 補充說明:

  • 驗證碼:

    請輸入計算結果(填寫阿拉伯數字),如:三加四=7